메인콘텐츠 바로가기

HI AIR KOREA Co., Ltd.

KOREAN

HOME

OFFSHORE

COOLING

AIR COOLED CONDENSING UNIT

HI AIR KOREA(HAK) offers wide range of AIR COOLED CONDENSING UNIT specifically design and built for offshore use suitable for highly corrosive environment.

Available options for unit construction are countless. It includes customized design and low weight assembly, hazardous area application.

HAK makes sure that these units are executed in a high quality finish, great for matching with FAN COIL UNIT in both accommodation areas and technical spaces.

HAK AIR COOLED CONDENSING UNIT is of remarkable versatility to suit any environment the unit will be placed on.

  • FEATURES

    SELECTION

    • Extensive range of condensing capacities
    • Customizable design for offshore applications

    CONSTRUCTION

    • Simple and compact design good for onboard space limitations
    • Stainless steel(SS316L) casing
    • High quality integrated components for maximum reliability
      • Equipped with built in directly coupled axial fan with motor and protection cover
      • Equipped with multi-pass crossed copper tube with copper fins condensing coil
      • Heresite coating for condensing coil
      • Equipped with hermetic reciprocating compressor
    • HFC refrigerants : R-404A, R-407C, R-134a
    • Power supply : 380/440/690Vac, 50/60Hz, 3-phase
    • High & low pressure gauges are mounted on front side
    • Starter is located in FAN COIL UNIT
    • Factory assembled, tested under strict quality standards

    MAINTENANCE

    • Easy installation and maintenance
  • OPTIONS
    • Stainless steel(SS316L) casing and epoxy coating
    • Heresite & UV coating for condensing coil
    • Compressor : scroll or screw type
    • Flexible connections and counter flanges for air outlet
    • Hazardous area application
    • Full performance test after connecting FAN COIL UNIT
  • CAPACITIES

    CAPACITY & DIMENSIONS

    • (ACCU design basis : Outdoor temp. 35 ℃)
    • (FCU design basis : Air inlet 27 ℃ RH 50 %, Air outlet 15 ℃ RH 90 %)
    MODEL CAPACITY FAN DIA. AIR FLOW POWER
    INPUT
    DIMENSION
    (mm)
    MIN.SERVICE SPACE
    (mm)
    kW mm m3/h kW WIDTH HEIGHT DEPTH FRONT RIGHT LEFT REAR
    HIC-03A 13.1 500 x 1EA 5,400 2.94 1,000 800 700 1,000 500 500 500
    HIC-05A 21.7 600 x 1EA 7,200 4.72 1,400 1,075 650 1,000 500 500 500
    HIC-08A 32.4 650 x 1EA 8,900 7.49 1,400 1,075 800 1,000 500 500 500
    HIC-10A 43.8 600 x 2EA 12,000 10.38 1,850 1,400 1,050 1,000 500 500 500
    HIC-15A 66.1 650 x 2EA 18,000 15.25 1,850 1,500 1,050 1,000 500 500 500
    HIC-20A 87.5 700 x 2EA 24,000 19.26 1,850 1,500 1,250 1,000 500 500 500