AIR HANDLING
FAN COIL UNIT & UNIT COOLER
Complete your navy air conditioning system with the reliable HI AIR KOREA(HAK) FAN COIL UNIT and UNIT COOLER!
HAK has developed different types of customizable FAN COIL UNIT and UNIT COOLER in response to the highly demanding room air requirements for use in navy applications.
HAK FAN COIL UNIT and UNIT COOLER for the navy ships are integrated with filter, fan, cooling coil and heating coil in one compact casing.
Navy FAN COIL UNIT and UNIT COOLER are qualified for impact, vibration and noise requirement according to U.S military standard.
Together with the other HAK air conditioning equipment, these HAK FAN COIL UNIT and UNIT COOLER are your partners for bringing quality air into your environment.
-
FEATURES
SELECTION
- Available cooling capacity for FAN COIL UNIT from 2.6 USRT to 12.6 USRT
- Available cooling capacity for UNIT COOLER from 0.9 USRT to 1.8 USRT
- Customized design for Navy applications
CONSTRUCTION
- Simple and compact designed for installation aboard vessels
- Steel casing with single skin
- Armarflex insulation
-
High quality integrated components for maximum reliability
- The fan’s mounting ensures low level of noise and vibrations
- Built in directly coupled centrifugal fan with motor for FAN COIL UNIT
- Axial fan with motor for UNIT COOLER
- The Demister filter is placed on the intake of return duct
- Copper tube with aluminum fins cooling coil
- Cooling medium : Chilled water
- Power supply : 440Vac, 60Hz, 3-phase
- Starter : Mounted on the wall near the FAN COIL UNIT and UNIT COOLER
- Factory assembled, tested in accordance with a recognized standards
MAINTENANCE AND QUALITY CONTROL
- Easy installation and maintenance
- Factory air flow rate test
-
Special performance test
- Impact test : MIL-STD-901D
- Vibration test : MIL-STD-167-1A
- Noise test : MIL-STD-740-1/2
-
OPTIONS
FAN COIL UNITS
- Flexible connections and counter flanges for air intake and outlet
- Electric heating coil
- Copper tube with Copper fins cooling coil
- 2-way control valve and auto balancing valve for chilled water
UNIT COOLER
- Copper tube with Copper fins cooling coil
- 2-way control valve and auto balancing valve for chilled water
- Ex-proof type
-
CAPACITIES
FCU - CAPACITY & DIMENSIONS(STANDARD)
(Design basis : Air inlet 27 ℃ RH 50 %, Air outlet 15 ℃ RH 90 %)
STANDARD TYPE FOR FAN COIL UNIT
MODEL HIF-ADE HIF-BDE HIF-CDE HIF-DDE HIF-EDE COOLING CAPACITY USRT 2.6 4.3 6.7 8.3 12.6 SUPPLY FAN
(COMEFRI)MODEL - TLZ 200T TLZ 225T TLZ 250T TLZ 280T TLZ 315T AIR FLOW RATE CMH 1,290 2,140 3,190 4,330 6,460 MOTOR kW 2.2 3.7 3.7 3.7 5.5 EXT. STATIC PRESSURE Pa 500 500 500 500 500 CHILLED WATER COIL CHILLED WATER FLOW RATE CMH 2.1 3.5 5.4 6.7 10.2 CHILLED WATER IN ℃ 6.7 6.7 6.7 6.7 6.7 CHILLED WATER OUT ℃ 10.4 10.4 10.4 10.4 10.4 CHILLED WATER PIPE DIAMETER - 25A 32A 32A 40A 50A ELEC. HEATING COIL
(OPTION)CAPACITY kW 10.0 16.0 20.0 23.0 25.0 DIMENSION LENGTH
(mm)1,118 1,220 1,295 1,422 1,422 WIDTH
(mm)711 812 940 940 1,200 HEIGHT
(mm)1,505 1,505 1,505 1,505 1,505 PRODUCT WEIGHT(Dry) kg 380 410 480 530 620 UC - CAPACITY & DIMENSIONS(STANDARD)
(Design basis : Air inlet 27 ℃ RH 50 %, Air outlet 15 ℃ RH 90 %)
STANDARD TYPE FOR UNIT COOLER
MODEL UC-A UC-B UC-C COOLING CAPACITY USRT 0.9 1.3 1.8 SUPPLY FAN IMPELLER DIAMETER mm 352 352 352 AIR FLOW RATE CMH 610 950 1,380 MOTOR kW 0.4 0.4 0.4 CHILLED WATER COIL CHILLED WATER FLOW RATE CMH 0.7 1.1 1.5 CHILLED WATER IN ℃ 6.7 6.7 6.7 CHILLED WATER OUT ℃ 10.4 10.4 10.4 CHILLED WATER PIPE DIAMETER - 20A 20A 25A DIMENSION LENGTH
(mm)1,282 1,282 1,282 WIDTH
(mm)925 925 925 HEIGHT
(mm)472 549 625 PRODUCT WEIGHT(Dry) kg 270 280 300 - DOCUMENTS