H₂ Charging station chillers

H₂ Charging station chillers

HI AIR KOREA provides various types of customized Hydrogen charging station chillers of high efficiency for hydrogen charging stations which are developed to meet the versatile requirements of clients and conditions by using the technology and know-how acquired through the experience in marine, offshore and industrial chiller production.

HI AIR KOREA chillers adopted PLC control system fro stable system control. The main Chiller includes inverter controlled compressors for cost effective operation by saving the power consumption and to ensure stable & reliable operation by preventing short cycling at fluctuating cooling load.

Hydrogen charging station chillers have various types as below;

Main Chillers for H₂ Charging Machine
- 36 kW Air Cooled Main Chiller
- 36 kW Water Cooled Main Chiller

Sub Chillers for H₂ Compressor
- 85 / 140 / 170 / 200 kW Air Cooled Sub Chillers

HI AIR KOREA does its best to provide total solutions by offering customized chillers used for the cooling demands of hydrogen charging stations from design, manufacturing and commissioning of entire cooling system.

  • FEATURES

    Main Chillers for H₂ Charging Machine

    AIR COOLED TYPE

    WATER COOLED TYPE

    General

    • Main Chiller supplies brine of -17.5℃ ~ -40.0℃ to cool the H₂ charging machine that produce 875 bar of compressed hydrogen as per SAE J2601 T40.

    Construction

    • Cost effective operation by saving the power consumption and prolonged lifetime by using inverter compressor (30~70Hz)
    • Fast response time control by electronic expansion valve and inverter compressor to cope with the sudden changes of cooling load
    • Efficient and stable control by SIEMENS CLIMATIX SERIES PLC which is optimized for air conditioning and refrigeration system.
    • Brine buffer tank of 180 Liter @ -40.0℃ ensures stable operation at peak cooling load.
    • Two independent refrigerant circuits for redundant operation
    • Dual reducing valves and pressure safety valves for Brine buffer tank prevent nitrogen overcharge and hydrogen ingress which can damage the charging machine.
    • Air cooled type main chiller can operate independently, which offers simple installation by eliminating other utilities.
    • Water cooled type main chiller provides stable operation even at highest summer temperature with lower noise level.
    • Proven performance and reliability by test and verification at various ambient conditions (-15 ℃ ~43℃).
    • Max noise level of 85 dB(A) at 1 m away from chiller

    Maintenance and Quality Assurance

    • Simple installation and maintenance
    • Pressure and leakage test before delivery
    • Performance test before delivery

    Sub Chillers for H₂ Compressor

    AIR COOLED TYPE

    General

    • Sub Chiller supplies chilled water of 20.0℃ to prevent H₂ compressor damage and ensure the best efficiency by cooling the H₂ compressor.

    Construction

    • Two independent refrigerant circuits for redundant operation (140/170/200 kW only)
    • Fast response time control by electronic expansion valve to cope with the sudden changes of cooling load from multiple H₂ compressors and water cooled type main chillers.
    • Efficient and stable control by SIEMENS CLIMATIX SERIES PLC which is optimized for air conditioning and refrigeration system.
    • Brine buffer tank @ 20.0℃ ensures stable operation at peak cooling load.
    • Environment friendly & low pressure type R-134a refrigerant can stably operate at highest summer (200 kW only).
    • Additional power saving if CMA (Cooling Module Assembly) is provided.
    • Max noise level of 85 dB(A) at 1 m away from chiller
    • Proven performance and reliability by test and verification at various ambient conditions (-15 ℃ ~ 43℃).

    Maintenance and Quality Assurance

    • Simple installation and maintenance
    • Pressure and leakage test before delivery
    • Performance test before delivery
  • OPTION

    MAIN CHILLER

    • Strainer for brine piping – Protection of equipment and components
    • Strainer for cooling water piping – Protection of equipment and components (for water cooled type)
    • Additional safety valve (25A) for hydrogen discharge – Protection for hydrogen ingress due to PCHE leakage
    • Nitrogen bottles on equipment skid – Provide nitrogen supply.

    SUB CHILLER

    • Strainer for cooling water piping – Protection of equipment and components
  • CAPACITIES

    MAIN CHILLER UNIT

    MAIN CHILLER UNIT 표
    TYPE TEMPERATURE CAPA REFRIGERANT CIRCUIT CONDENSER TYPE
    HRS L - 036 D A
    (Hydrogen Refuelling Station) (Low temp. chiller) (kW) S : Single
    D : Dual
    A : Air cooled condenser
    W : Water cooled condenser

    SUB CHILLER UNIT

    SUB CHILLER UNIT 표
    TYPE TEMPERATURE CAPA REFRIGERANT CIRCUIT CONDENSER TYPE
    HRS M - 085 S A
    140 D
    170 D
    200 D
    (Hydrogen Refuelling Station) (Medium temp. chiller) (kW) S : Single
    D : Dual
    A : Air cooled condenser
    W : Water cooled condenser

    MaiN CHILLER Specification

    수소충전기용 냉동기(MaiN CHILLER) 사양 표
    DESCRIPTION HRSL-036DA HRSL-036DW REMARK
    COOLING CAPACITY kW 36.2 36.0
    USRT 10.3 10.2
    LEG. RT 17.26 15.06
    REFRIGERANT R-507A
    COMPRESSOR TYPE 2 STAGE SEMI HERMETIC RECIPROCATING
    CAPACITY CONTROL INVERTER INVERTER
    Q'TY EA 2 2
    CONDENSER TYPE AIR COOLED FIN AND TUBE HEAT EXCHANGER BRAZED PLATE TYPE HEAT EXCHANGER
    CAPACITY kW 75.8 65.0
    FAN MAKER HI AIR KOREA -  
    TYPE AIRFOIL AXIAL FLOW FAN -
    Q'TY EA 4 -
    FAN MOTOR SPECIFICATION 0.75kW, 380V 6Pole 1120RPM, INVERTER CONTOROL -
    Q'TY EA 4 -
    ECONOMIZER TYPE BRAZED PLATE TYPE HEAT EXCHANGER
    Q'TY EA 2
    EXPANSION
    VALVE
    TYPE ELECTRONIC CONTROL
    Q’TY 4 4
    EVAPORATOR TYPE BRAZED PLATE TYPE HEAT EXCHANGER  
    Q'TY EA 1
    CIRCULATION
    PUMP
    TYPE MAGNETIC DRIVE TURBINE PUMP
    FLOW / WATER HEAD CMH, m 7.5(125 LPM) / 30
    MOTOR kW 3.7
    Q'TY EA 1
    BRINE PIPE CONNECTION STS304 JIS 10K 40A M-2 SILICONE
    WATER TANK L 200
    NORMAL
    POWER
    CONSUMPTION
    kW 44.5 32.7
    MAX
    POWER
    CONSUMPTION
    kW 66.4 56.3
    DIMENSION mm (W)1,900 x
    (L)1,900 x
    (H)2,590
    (W)1,900 x
    (L)1,900 x
    (H)1,920

    ※ Main chillers are designed at ambient temperature of 35℃, and subject to change depending on the site condition, performance development and quality requirements.

    SUB CHILLER specification

    수소압축기용 냉동기(SUB CHILLER) 사양
    DESCRIPTION HRSM-085SA HRSM-140DA HRSM-170DA HRSM-200DA REMARK
    COOLING CAPACITY kW 85 140 170 200
    USRT 24.2 39.8 48.3 56.9
    REFRIGERANT R-407C R-134a
    COMPRESSOR TYPE HERMETIC SCROLL HERMETIC SCROLL HERMETIC SCROLL HERMETIC SCROLL
    CAPACITY CONTROL ON/OFF ON/OFF ON/OFF ON/OFF
    Q'TY EA 1 2 2 2
    CONDENSER TYPE AIR COOLED FIN AND TUBE HEAT EXCHANGER
    CAPACITY kW 107.7 184.8 215.4 246.6
    Q'TY EA 2 4 4 4
    ACCU FAN MODEL Ø700 Ø700 Ø700 Ø710
    TYPE PROPELLER FAN AIRFOIL AXIAL FLOW FAN
    Q'TY EA 2 4 4 4
    ACCU FAN
    MOTOR
    SPECIFICATION 0.88kW, 380V 3 Ph 6P 0.88kW, 380V 3 Ph 6P 0.88kW, 380V 3 Ph 6P 1.1kW, 380V 3 Ph 6P
    Q'TY EA 2 4 4 4
    EXPANSION
    VALVE
    TYPE ELECTRONIC CONTROL
    Q'TY EA 1 2 2 2
    EVAPORATOR TYPE BRAZED PLATE TYPE HEAT EXCHANGER
    Q'TY EA 1 1 1 1
    WATER FLOW RATE EG 50% m³/h 17.3 28.5 34.7 40.8 20℃ / 25℃
    WATER PIPING LINE STS304 JIS 10K 50A JIS 10K 50A JIS 10K 65A JIS 10K 80A
    CIRCULATION
    PUMP
    TYPE IN-LINE CENTRIFUGAL PUMP
    FLOW / WATER HEAD m³/h, m 17.3 / 30 28.5, 30 34.7, 30 40.8 / 30
    Q'TY EA 1 1 1 1
    WATER TANK L 226 380 474 558
    NORMAL
    POWER
    CONSUMPTION
    kW 28.1 53.7 56.3 55.8
    MAX
    POWER
    CONSUMPTION
    kW 36.0 70.1 72.1 71.5
    DIMENSION mm (W)1,500 x
    (L)1,900 x
    (H)2,600
    (W)1,900 x
    (L)1950 x
    (H)2,600

    ※ Sub chillers are designed at ambient temperature of 35℃, and subject to change depending on the site condition, performance development and quality requirements.